![]() |
Decay constant for singlet oxygen in the solvent: Benzene-d6 | ![]() |
Lifetime is 5.9 x 10–4 s
Decay rate is 1.7 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Chr.
Lifetime is 7.8 x 10–4 s
Decay rate is 1.3 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is C60 or C70.
Lifetime is 6.8 x 10–4 s
Decay rate is 1.5 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, TPP or PHO.
Lifetime is 6.5 x 10–4 s
Decay rate is 1.5 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Np, Pz and BP.
Lifetime is 6.8 x 10–4 s
Decay rate is 1.5 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is An.
Decay rate is 1.5 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 6.2 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed radiolysis, luminescence decay
Sensitizer is 2-ACN.
Lifetime is 7.9 x 10–4 s
Decay rate is 1.3 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 7.7 x 10–4 s
Decay rate is 1.3 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Pz.
Lifetime is 6.3 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Pur.
Lifetime is 3.8 x 10–4 s
Decay rate is 2.6 x 103 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is An.
Lifetime is 6.3 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HPDME.
Lifetime is 7.0 x 10–4 s
Decay rate is 1.4 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, RB or TPP.
Lifetime is 3.1 x 10–4 s
Decay rate is 3.2 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is PdMPDME.
Lifetime is 6.2 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Cercosporin.
Lifetime is 5.5 x 10–4 s
Decay rate is 1.8 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME.
Lifetime is 6.8 x 10–4 s
Decay rate is 1.5 x 103 s–1
Experimental method: continuous photolysis, luminescence intensity
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone
rel. to kd = 4.0 x
104 s–1 in benzene.
Lifetime is 1 x 10–3 s
Decay rate is 1 x 103 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 2-ACN;
Substrate is DPBF
cor. for kS.
Lifetime is 7 x 10–4 s
Decay rate is 2 x 103 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 3,6-Bis(dibutylamino)phenothiazinium bromide;
Substrate is Rub.
Lifetime is 3.6 x 10–5 s
Decay rate is 2.8 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.