Decay constant for singlet oxygen in the solvent: Deuterium oxide | ![]() |
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ru(bpy)32+
pH = 6.8.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, TPP or PHO.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–, CAPcS, SnTPPSCl24– or
ZnPCS3–
Soln. contg. 2 x 10–3 mol L–1
phosphate buffer and 1% NaCl wt/wt.
Lifetime is 6.0 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is 4-Thiouridine.
Lifetime is 7.0 x 10–5 s
Decay rate is 1.4 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB or H2TPPS4–
pD = 3.
Lifetime is 6.4 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB, TPP or H2TPPS4–
1.0 mol L–1 NaOD.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 6.1 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Chlorin e6
pD = 8.1.
Lifetime is 6.5 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HP.
Lifetime is 7.0 x 10–5 s
Decay rate is 1.4 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 5.2 x 10–5 s
Decay rate is 1.9 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is AlCl(tspc)
pH = 7.
Lifetime is 6.0 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ru(bpy)32+
pH = 7; O2 saturated.
Lifetime is 5.8 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is 2-AnS
pH = 7.
Lifetime is 6.7 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is UP.
Lifetime is 6.0 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–.
Lifetime is 6.7 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RF
pD = 7.
Lifetime is 5.9 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–
pH = 7.
Lifetime is 6.3 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
1O2* from NDPO2.
Lifetime is 6.3 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is C6H5CO2–.
Lifetime is 6.7 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TMpyP4+.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–.
Lifetime is 4.4 x 10–5 s
Decay rate is 2.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is H2TPPS4–.
Lifetime is 4.4 x 10–5 s
Decay rate is 2.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is PdTPPS4–.
Lifetime is 6.7 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Sulfo- and carboxyanthracenes.
Lifetime is 5.4 x 10–5 s
Decay rate is 1.9 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is PBA;
Substrate is Crocetin
pD = 8.4.
Lifetime is 5.8 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB or Th.
Lifetime is ~4.5 x 10–5 s
Decay rate is ~2.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HP.
Decay rate is 1.9 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB;
Substrate is ADPA.