Decay constant for singlet oxygen in the solvent: Acetone-d6 | ![]() |
Lifetime is 9.9 x 10–4 s
Decay rate is 1.0 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, TPP or PHO.
Lifetime is 6.4 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB
varied [S] and extrapolated to [S] = 0.
Lifetime is 1.2 x 10–4 s
Decay rate is 8.2 x 103 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is An.
Lifetime is 5.8 x 10–4 s
Decay rate is 1.7 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HPDME.
Lifetime is 8.6 x 10–4 s
Decay rate is 1.2 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, RB or TPP.
Lifetime is 3.9 x 10–4 s
Decay rate is 2.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is PdMPDME.
Lifetime is 8.4 x 10–4 s
Decay rate is 1.2 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HP.
Lifetime is 6.9 x 10–4 s
Decay rate is 1.4 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME.
Lifetime is 7.7 x 10–4 s
Decay rate is 1.3 x 103 s–1
Experimental method: continuous photolysis, luminescence intensity
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone
rel. to kd = 4.0 x
104 s–1 in benzene.
Lifetime is 8 x 10–4 s
Decay rate is 1 x 103 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 2-ACN;
Substrate is Rub
cor. for kS.