Decay constant for singlet oxygen in the solvent: Acetonitrile | ![]() |
Lifetime is 7.1 x 10–5 s
Decay rate is 1.4 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is DCA.
Lifetime is 7.7 x 10–5 s
Decay rate is 1.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ac.
Decay rate is 1.4 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Chr
rate decreased linearly with magnetic field strength, by 4-7% at 21kG.
Lifetime is 6.0 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ru(bpy)32+.
Lifetime is 7.7 x 10–5 s
Decay rate is 1.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, TPP or PHO.
Lifetime is 8.0 x 10–5 s
Decay rate is 1.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is 1-MeNp.
Decay rate is 1.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ac.
Lifetime is 7.5 x 10–5 s
Decay rate is 1.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is OMAPB
extrapolated to zero laser dose.
Lifetime is 8.3 x 10–5 s
Decay rate is 1.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB or H2TPPS4–.
Lifetime is 3.3 x 10–5 s
Decay rate is 3.0 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is (C6H5)2CO.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB.
Lifetime is 6.0 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is Ac.
Lifetime is 6.7 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Np, Biph, or Fl.
Decay rate is 1.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ac.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is An.
Lifetime is 8.7 x 10–5 s
Decay rate is 1.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB
from high intensity photolysis; M = 1O2*.
Lifetime is 5.4 x 10–5 s
Decay rate is 1.9 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
1O2* from 9,10-diphenylanthracene endoperoxide.
Lifetime is 4.8 x 10–5 s
Decay rate is 2.1 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is An.
Lifetime is 5.6 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is 2-ACN.
Lifetime is 3.6 x 10–5 s
Decay rate is 2.8 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is Ery.
Lifetime is 5.8 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HPDME.
Lifetime is 6.4 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME.
Lifetime is 3.5 x 10–5 s
Decay rate is 2.9 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is An;
Substrate is DPBF.
Lifetime is 6.1 x 10–5 s
Decay rate is 1.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB.
Lifetime is 6.8 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 5.4 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME.
Lifetime is 5.8 x 10–5 s
Decay rate is 1.7 x 104 s–1
Experimental method: continuous photolysis, luminescence intensity
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone
rel. to kd = 4.0 x
104 s–1 in benzene.
Lifetime is 9.2 x 10–5 s
Decay rate is 1.1 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 2-ACN;
Substrate is DPBF
cor. for kS.
Lifetime is 5.7 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.
Lifetime is 3 x 10–5 s
Decay rate is 3 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.